  data sheet date vortex flowmeter (eggs delta) EDS6-121A aug. 5, 2005 fmp, m this instrument is a karman vortex flowmeter made of pps resin that can be used both for liquid and gas. it has no moving parts. it does not shut the flow even in the case of an emergency, which makes it most suitable for not only in general flow control applications but also in important washing processes and cooling processes, and in the ter- minal consumption control such as in factory air control. the exclusive monitoring instrument is a battery charged type and does not need external power supply. orienta- tion of the indicator can be adjusted freely to easy-to-see direction. features 1. the monitoring mode can be changed freely from total flow monitoring to instantaneous flow rate monitoring, and vice versa, by an externally mounted mode switch. 2. a rainproof type is available for outdoor use as well as for indoor use. 3. the highly durable structure with no moving parts does not impose limitations to its mounting positions. 4. the instrument is highly resistive to fouling by fluid, and its structure facilitates cleaning of its interior. 5. remotely controllable external output (total pulse or instantaneous analog) is available.
fmp, m 2 item description for liquid type for gas fmp20 fmp30 8mm r 1 /2 male screw  or rc 1 /4 female screw fmp21 fmp31 15mm r 3 /4 male screw  or rc 1 /2 female screw fmp22 fmp32 25mm r1 1 /4 male screw  or rc1 female screw nominal diameter, connection for liquid for gas water air water air fluid fluid flow rate range (l/min) * permissible ambient temper- ature range environment maximum pressure accuracy reproducibility pressure loss (kpa) [see fig. 1] main body material indicator (lcd digital display) (1) total flow: 8 digits (2) instantaneous flow rate (per hour): 5 digits (3) instantaneous flow rate (per minute): 5 digits (4) resettable total flow: 7 digits (1), (2), (3), or (4) can be selected by push button. flow rate unit [l, m 3 , g, kg, t, l (normal), m 3 (normal)] and decimal point are indicated on lcd. (orientation of the indicator can be adjusted freely over 360 .)  * alarm is indicated with led (red). battery type output signal externally energized type battery type externally energized type cable power supply structure backup (if with indicator) 1.17 to 15 18 to 90 fmp2s fmp3s 4mm r 3 /8 male screw  or rc 1 /4 female screw 0.4 to 4 7.2 to 17 2.8 to 45 55 to 283 - 10 to +80 c (no condensation allowed) water, pure water, or others (non-corrosive, non-inflammable) air, nitrogen, oxygen, argon, or others (non-inflammable gas) - 20 to +50 c 0.98mpa 3% of full-scale measurement (see fig. 1) 0.5% length of straight pipe upstream side: 7d or more, downstream side: 3d or more (see fig. 2) 0.12 to 34.3 0.06 to 1.52 0.31 to 31 0.13 to 0.7 pps resin (polyphenylene sulfide) none 4 to 20 ma dc analog (instantaneous flow rate) (see fig. 3 load resistance range); or pulse output (open collector).  rated values: 30 v dc, 20 ma. on voltage: 1 v or less. pulse width: 30 ms (correct pulse) or 1 ms (non-correct pulse).  ... if with indicator  duty ratio about 1:1 (non-correct pulse) ... if without indicator alarm output (h, l) ... open collector. rated values: 30 v dc, 20 ma. on voltage: 1 v or less. 5-core shielded cable (1 m) ... if with indicator, for externally energized type 3-core shielded cable (1 m) ... if without indicator lithium battery unit. life time: 4 years (at normal temperature) ... with weak battery alarm function. 12 to 45 v dc (type code 6th digit: 1) 12 to 24 v dc (type code 6th digit: 0) outdoor use (rainproof type), non-explosion-proof type. direct sunshine not allowed. parameter settings and total value are held in eeprom 8.3 to 133 167 to 850 *: flow rate range may vary according to the viscosity, temperature, and pressure of the fluid. specifications (type: fmp)
3 code symbols < eggs delta > 45678 2 910 liquid gas 2 3 4mm equivalent 8mm equivalent 15mm equivalent 25mm equivalent s 0 1 2 description digit note 4 5 9 p s without (battery type) correct pulse output analog output non-correct pluse output upper/lower limit alarm output output of correct pluse and upeer/lower limit alarm output of non-correct pulse and upeer/lower limit alarm 7 0 1 2 3 4 5 6 6 1 with indicator 82 digit fmp waterproof type 10 w pps (r male screw) sus (rc female screw) < eggs delta pulse > 45678 1 910 liquid gas 2 3 4mm equivalent 8mm equivalent 15mm equivalent 25mm equivalent s 0 1 2 description digit 4 5 9 p s non-correct pluse output, dividing frequency 1/1 (for liquid) non-correct pluse output, dividing frequency 1/10 (for gas) non-correct pluse output, dividing frequency 1/100 (for special fluid) 7 7 8 9 6 0 without 81 digit fmp waterproof type 10 w pps (r male screw) sus (rc female screw) indication and output unit (standard setting) (2) gas nomal diameter (mm) 4 8 15 25 units of integration and corrected output 0.01 l 0.1 l 1l 1l instantaneous flow rate 1 l/h 0.01 l/min 10 l/h 0.1 l/min 100 l/h 1 l/min 100 l/h 1 l/min nominal output pulse unit (ml/p) 0.08900 0.4408 2.363 12.66 nomal diameter (mm) 4 8 15 25 units of integration and corrected output 0.1 l 1l 1l 10 l instantaneous flow rate 10 l/h 0.1 l/min 100 l/h 1 l/min 100 l/h 1 l/min 1000 l/h 10 l/min nominal output pulse unit (ml/p) 0.8900 4.408 23.63 126.6 (1) liquid
fmp, m 4 10 5 0 - 5 -10 39.2 29.4 19.6 9.8 flow rate (%) 3% of full-scale measurement 8 15 25 air 010203 0405060708090100 instrumental deviation (%) pressure loss (kpa) water instrumental deviation and pressure loss [fig. 1] load resistance range [fig. 3] 1,550 600 300 power voltage (vdc) 024 12 37 45 operation range load resistance ( ? ) straight pipe length [fig. 2] as a rule, secure the straight pipe length of at least 7d up- stream and 3d downstream (d: flowmeter inner diameter). for actual straight pipe length, see table below. pay attention to following items for securing the accuracy. l2 l1 d: internal diamete of flowmeter pipe eggs delta input direction nominal diameter (mm) 4 8 (pps) 8 (scs14a) 15 25 inner diameter (mm) 8.5 13 8.5 14 24.5 upstream (l1) (mm) 59 or more 91 or more 59 or more 98 or more 171 or more downstream (l2) (mm) 25 or more 39 or more 25 or more 42 or more 73 or more (1) use a connecting pipe of an inner diameter same as or more than that of main body. (2) if there is ?brupt expansion of piping diameter?up- stream the flowmeter such as metering valve, diffuser, etc., get at least 50d away. (3) provide a regulating valve downstream the flowmeter.
5 outline diagram (unit: mm) with indicator (code symbol 6th digit:1) < in case of pps (r male screw ) ?code symbol 9th digit:p > < in case of sus (rc female screw ) ?code symbol 9th digit:s > h2 45 l 39 24 w 65 h1 type nominal diameter d rl wh 1h 2 mass (g) fmp 0 fmp 1 2 3 2 3 2 3 8 rc 1 /4 91 50 29 102 660 fmp s 2 3 48.5 8.5 rc 1 /4 91 50 29 102 660 15 14 rc 1 /2 91 50 29 102 660 fmp 2 25 24.5 rc 1 126 46 46 119 960 internal diameter of main unit () internal diameter d 4-m4 (threaded hole for fixing main unit) l nominal diameter 24 internal diameter d 39 r power supply /output cable length: 1 m 83 65 w 45 h2 h1 indicator (8 digit lcd) orientation of the indicator can be adjusted to easy-to-see direction. indication reset switch alarm 2 indicator led * alarm 1 indicator led * mode switch 4-m4 (threaded hole for fixing main unit) kgltm 3 /hmin(nomal) mr ode al1 delta al2 eset e s g g *n ot provided if without output signal (battery type/code symbol 7th digit: 0) type d rl wh 1h 2m ass (g) fmp 0 fmp 1 2 3 2 3 2 3 813r 1 /2 80 32 29 102 285 fmp s 2 3 4 8.5 r 3 /8 80 32 29 102 285 15 14 r 3 /4 85 32 29 102 290 fmp 2 25 24.5 r 1 1 /4 120 46 46 119 420 internal diameter of main unit ()
fmp, m 6 outline diagram (unit: mm) without indicator (code symbol 6th digit:0) < in case of pps (r male screw ) ?code symbol 9th digit:p > < in case of sus (rc female screw ) ?code symbol 9th digit:s > 39 h2 d 24 36 l w h1 27 7.5 nominal r of screw transmission cable 3-core shielded cable (1m) type nominal diameter d rl wh 1h 2m ass (g) fmp 0 fmp 1 2 3 2 3 2 3 813r 1 /2 80 32 29 68 270 fmp s 2 3 4 8.5 r 3 /8 80 32 29 68 270 15 14 r 3 /4 85 32 29 68 280 fmp 2 25 24.5 r 1 1 /4 120 46 46 85 410 internal diameter of main unit () 4-m4 (threaded hole for fixing main unit) 51 39 h2  d 24 36 w h1 27 7.5 transmission cable 3-core shielded cable (1m) nominal r of screw l type nominal diameter d rl wh 1h 2 mass (g) fmp 0 fmp 1 2 3 2 3 2 3 8 rc 1 /4 91 50 29 68 650 fmp s 2 3 4 8.5 8.5 rc 1 /4 91 50 29 68 650 15 14 rc 1 /2 91 50 29 68 650 fmp 2 25 24.5 rc 1 126 46 46 85 950 internal diameter of main unit () 4-m4 (threaded hole for fixing main unit)
7 connection diagram (with 1m cable) with indicator (code symbol 6th digit:1) ? polarity wire color brown gray white yellow green description sup (and analog output) sig. 1 ... alarm 1 output (upper limit/lower limit) sig. 2 ... alarm 2 output (upper limit/lower limit) sig. 3 ... correct/non-correct pulse output com fmp sup (brown) analog output 4 to 20ma com (green) 12 to 45v dc 12 to 45v dc 12 to 45v dc 12 to 45v dc max. 30v max. 30v max. 30v max. 20ma max. 20ma max. 20ma max. 20ma max. 20ma max. 20ma fmp sup (brown) sig1 (gray) sig2 (white) com (green) max. 30v max. 30v max. 30v fmp sup (brown) sig1 (gray) sig2 (white) sig3 (yellow) com (green) sup (brown) sig3 (yellow) com (green) fmp fmp sup (brown) sig3 (yellow) com (green) sup. sig. 0v (dc13.5v) integrating meter fmm note: analog output and pulse output or upper/lower limit alarm cannot be combined. pulse output (open corrector) fmp brn (brown) (+) wht (white) ( - ) grn (green) 12 to 24v dc without indicator (code symbol 6th digit:0)
fmp, m 8 overview this instrument is a compact type lcd display counter that receives pulse signal from vortex flowmeter and indicates total flow and digital instantaneous flow rate (with power supply for the oscillator built in). features 1. one-chip cpu mounted on this instrument has permit- ted many functions. pressing pushbutton enables switching to the follow- ing 4 display modes. q total flow, w zero reset total, e instantaneous flow rate (switching between per hour display and per minute display is possible.), r meter coefficient 2. this instrument has a function of a scaler and of a di- vider. flush mount type wall type integrating meter (type: fmm) specifications 3. it converts input pulse signal representing flow rate into an analog signal through built-in f/i conversion circuit. (option) 4. equipped with pulse output before or after the correc- tion item description display method items to be displayed weak battery voltage alarm trigger level response pulse power supply for the oscillator backup function ambient temperature power voltage power consumption insulation resistance withstand voltage mass case finish color of the instrument frame types of signals capacity on-state voltage pulse width signal load resistance conversion accuracy ripple time constant   output signal   capacity  on resistance lcd height of letters: 12.7mm pressing "mode" switch allows the following display modes to rotate. (mode display such as b1, b2, and c is displayed on the most significant and the second digit of the display window.) *: not displayed when "select" switch is turned to "0" or "8". when "select" switch is turned to "4" or "c", the values of the above 7 items are displayed. the setting of "divided value", "meter coefficient", and "number of cycle samples" can be changed easily by the operation on the front panel of this instrument. however, do not change them except when the change is unavoidable, because the setting has been adjusted to meet the specifications of the flowmeter combined to this instrument. **: effectively indicated only when the input pulse has small frequency variation. "batt" blinks. 3v dc hysteresis 0.8v dc 200hz (50hz in the case of contact input)?.standard note that it can be followed up to 2khz by setting the input division to 1/10 or 1/100. when the scaler value is more tha n 1, 150hz max. 13.5v dc or 24v dc, 50ma, with overcurrent protection open collector pulse, corrective pulse (the same unit as the display), standard?r non-corrective pulse 30v dc, 50ma max. 1.5v dc max. 1ms, 50ms, 100ms, 250ms 4 to 20ma dc and 1 to 5v dc current output: 350 ? max. when output voltage is short-circuited: 600 ? max. output voltage: 1m ? min. within 0.1% of the full scale within 1% of the full scale at 10% of the full scale 4(2) to 19.99hz: 6.5s [the value in ( ) shows the value when an internal step-up circuit is used.] full scale puls 20 to 199.9hz: 2.1s 200 to 2000hz: 1.5s open mos-fet 2 230 v ac/340 v dc, 200 ma or less 16 ? or less (leakage current 1 a or less when off) 0.0001 to 1.9999, adjustable in steps of 0.0001 selection of the unit to be displayed: 1/1, 1/10, or 1/100 the counter display value and setting are backed up by built-in e 2 prom -10 to +50 c 85 to 264v ac, 50/60hz 16va max. batch power terminals and ground terminal, 10m ? or more, 500v dc megger batch power terminals and ground terminal, 1500v ac, 1 minute approx. 0.6kg (flush mount type), approx. 0.8kg (wall type) resin frame and aluminum case (flush mount type), plastic case (wall type) munsell color code n1.5 equivalent scaler dividing display input signal output signal pulse analog (option) upper/lower limit alarm (option) setting mode ? b1 b2 c d f a digit 8 5 5 7 1 5 3 total flow instantaneous flow rate instantaneous flow rate total flow divided value* meter coefficient* number of cycle samples display not resettable to 0 per hour per minute resettable to 0 0 (1/1), 1 (1/10), 2 (1/100) 0.0001 to 1.9999 1 to 128 description ** **
9 outline diagram (unit: mm) code symbols (flush mount type) panel cutout dimensions 4 fmm 5678 3 910 85 to 264v ac 50/60hz input signal 3-wire open corrector pulse output signal (open collector) pulse width: approx. 1ms pulse width: approx. 50ms pulse width: approx. 100ms pulse width: approx. 250ms none (standard) analog output (4 to 20ma dc / 1 to 5v dc) and upper/lower limit alarm output additional function none (standard) with a battery for lighting the lcd when power is off flush mount type wall type description digit 4 5 6 7 8 9 10 6 2 5 6 7 0 1 3 0 1 1 2 7 digit min. 70 min. 120 92 45 105.5 +0.6 0 +0.8 0 ?eset?button ?larm1?led* ?ode?button ?larm2?led* 96 48 6.5 reset mode alarm1 alarm2 batt * only for analog/alarm output (code symbol 7th digit: ?? mounting bracket upper terminals lower terminals
fmp, m 10 outline diagram (unit: mm) (wall type) connections 125 96 110 90 75 48 59.7 134.5 53 6.5 3 reset mode alarm1 alarm2 batt mounting hole 4 - 5.4 applied cable diameter: 5.5 to 7 alarm1 out alarm2 out open mos-fet


▲Up To Search▲   

 
Price & Availability of EDS6-121A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X